Balance Point

The outdoor temperature at which a heat pump's heating capacity equals the home's heat loss — below this, backup heat is needed.

The balance point is the outdoor temperature at which a heat pump’s heating capacity exactly matches your home’s heat loss rate. Above the balance point, the heat pump handles 100% of demand. Below it, supplemental backup heat (electric resistance strips or a gas furnace in dual-fuel mode) kicks in to make up the difference.

Why this matters

The balance point depends on three things:

  • Your home’s heating load (Manual J output)
  • The heat pump’s capacity at various outdoor temperatures
  • How the system is sized (oversize the heat pump, lower the balance point)

For most Colorado dual-fuel installs, we target a balance point around 20-30°F. The heat pump handles all heating hours above that, the furnace takes over below. That split typically results in the heat pump doing 80-90% of the season’s heating work at 250-400% efficiency.

“Economic” vs. “thermal” balance point

The thermal balance point is when capacity equals load. The economic balance point is when operating costs of heat pump vs. backup furnace cross over — usually a few degrees colder. Modern smart thermostats can be configured for either.

Related: Dual-Fuel, Heat Pump, Cold-Climate Heat Pump, Manual J.